test_sglang.py 17.4 KB
Newer Older
1
2
3
# SPDX-FileCopyrightText: Copyright (c) 2025 NVIDIA CORPORATION & AFFILIATES. All rights reserved.
# SPDX-License-Identifier: Apache-2.0

4
5
6
7
# TODO: Update to use dynamic port allocation (allocate_free_port) for parallel execution
# Currently uses hardcoded ports: FRONTEND_PORT (8000), system ports (8081, 8082)
# See tests/fault_tolerance/migration/test_sglang.py for dynamic port pattern

8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
import logging
import os
import shutil
import time

import pytest

from tests.conftest import NatsServer
from tests.fault_tolerance.etcd_ha.utils import (
    DynamoFrontendProcess,
    EtcdCluster,
    send_inference_request,
    wait_for_processes_to_terminate,
)
from tests.utils.constants import FAULT_TOLERANCE_MODEL_NAME
from tests.utils.engine_process import FRONTEND_PORT
from tests.utils.managed_process import ManagedProcess
from tests.utils.payloads import check_health_generate, check_models_api

logger = logging.getLogger(__name__)


class DynamoWorkerProcess(ManagedProcess):
    """Process manager for Dynamo worker with SGLang backend and ETCD HA support"""

    def __init__(self, request, etcd_endpoints: list, mode: str = "agg"):
        """
        Initialize SGLang worker process with ETCD HA support.

        Args:
            request: pytest request object
            etcd_endpoints: List of ETCD endpoints
            mode: One of "agg", "prefill", "decode"
        """
        command = [
            "python3",
            "-m",
            "dynamo.sglang",
            "--model-path",
            FAULT_TOLERANCE_MODEL_NAME,
            "--served-model-name",
            FAULT_TOLERANCE_MODEL_NAME,
            "--page-size",
            "16",
            "--tp",
            "1",
            "--trust-remote-code",
        ]

        # Add mode-specific arguments
        if mode == "agg":
            # Aggregated mode - add skip-tokenizer-init
            command.append("--skip-tokenizer-init")
        else:
            # Disaggregated mode - add disaggregation arguments
            command.extend(
                [
                    "--disaggregation-mode",
                    mode,
                    "--disaggregation-bootstrap-port",
                    "12345",
                    "--host",
                    "0.0.0.0",
                    "--disaggregation-transfer-backend",
                    "nixl",
                ]
            )

        health_check_urls = [
            (f"http://localhost:{FRONTEND_PORT}/v1/models", check_models_api),
            (f"http://localhost:{FRONTEND_PORT}/health", check_health_generate),
        ]

        # Set port based on worker type
        if mode == "prefill":
            port = "8082"
            health_check_urls = [(f"http://localhost:{port}/health", self.is_ready)]
        elif mode == "decode":
            port = "8081"
            health_check_urls = [(f"http://localhost:{port}/health", self.is_ready)]
        else:  # agg (aggregated mode)
            port = "8081"

        # Set debug logging and ETCD endpoints
        env = os.environ.copy()
        env["DYN_LOG"] = "debug"
        env["ETCD_ENDPOINTS"] = ",".join(etcd_endpoints)
        env["DYN_SYSTEM_USE_ENDPOINT_HEALTH_STATUS"] = '["generate"]'
        env["DYN_SYSTEM_PORT"] = port

        # Set GPU assignment for disaggregated mode
        if mode == "decode":
            env["CUDA_VISIBLE_DEVICES"] = "1"  # Use GPU 1 for decode worker
        elif mode == "prefill":
            env["CUDA_VISIBLE_DEVICES"] = "0"  # Use GPU 0 for prefill worker
        # For agg (aggregated) mode, use default GPU assignment

        # Set log directory based on worker type
        log_dir = f"{request.node.name}_{mode}_worker"

        # Clean up any existing log directory from previous runs
        try:
            shutil.rmtree(log_dir)
            logger.info(f"Cleaned up existing log directory: {log_dir}")
        except FileNotFoundError:
            pass

        super().__init__(
            command=command,
            env=env,
            health_check_urls=health_check_urls,
            timeout=300,
            display_output=True,
            terminate_existing=False,
            # Ensure any orphaned SGLang engine cores or child helpers are cleaned up
            stragglers=[
                "SGLANG:EngineCore",
            ],
            straggler_commands=[
                "-m dynamo.sglang",
            ],
            log_dir=log_dir,
        )

        self.mode = mode

    def is_ready(self, response) -> bool:
        """Check the health of the worker process"""
        try:
            data = response.json()
            if data.get("status") == "ready":
                logger.info(f"{self.mode.capitalize()} worker status is ready")
                return True
            logger.warning(
                f"{self.mode.capitalize()} worker status is not ready: {data.get('status')}"
            )
        except ValueError:
            logger.warning(
                f"{self.mode.capitalize()} worker health response is not valid JSON"
            )
        return False


@pytest.mark.sglang
@pytest.mark.gpu_1
@pytest.mark.e2e
@pytest.mark.model(FAULT_TOLERANCE_MODEL_NAME)
155
@pytest.mark.timeout(600)
156
157
def test_etcd_ha_failover_sglang_aggregated(request, predownload_models):
    """
158
    Test ETCD High Availability with repeated node failures and recoveries using SGLang.
159
160
161
162

    This test:
    1. Starts a 3-node ETCD cluster
    2. Starts NATS, frontend, and an SGLang worker
163
164
165
166
167
168
169
170
    3. Cycles through each of the 3 replicas:
       - Terminate the replica by index
       - Send inference request to verify system still works
       - Restart the terminated node

    This ensures testing of:
    - ETCD leader termination
    - Frontend/worker disconnection from their connected ETCD replica
171
172
173
174
175
176
    """
    # Step 1: Start NATS server
    with NatsServer(request):
        logger.info("NATS server started successfully")

        # Step 2: Start 3-node ETCD cluster
177
178
        num_replicas = 3
        with EtcdCluster(request, num_replicas=num_replicas) as etcd_cluster:
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
            logger.info("3-node ETCD cluster started successfully")

            # Get the endpoints for all ETCD nodes
            etcd_endpoints = etcd_cluster.get_client_endpoints()
            logger.info(f"ETCD endpoints: {etcd_endpoints}")

            # Step 3: Start the frontend with ETCD endpoints
            with DynamoFrontendProcess(request, etcd_endpoints):
                logger.info("Frontend started successfully")

                # Step 4: Start an SGLang worker
                with DynamoWorkerProcess(request, etcd_endpoints, mode="agg"):
                    logger.info("SGLang worker started successfully")
                    # Small wait to ensure worker is fully ready
                    time.sleep(2)

195
196
197
                    # Step 5: Send initial inference request to verify system is working
                    logger.info("Sending initial inference request")
                    result = send_inference_request("What is 2+2? The answer is")
198
                    assert (
199
200
                        "4" in result.lower() or "four" in result.lower()
                    ), f"Expected '4' or 'four' in response, got: '{result}'"
201

202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
                    # Step 6: Cycle through each replica to terminate/verify/restart
                    for i in range(num_replicas):
                        # Terminate a replica
                        logger.info(f"Iteration {i}: Terminating replica etcd-{i}")
                        etcd_cluster.terminate_replica(i)

                        # Send inference request to verify system still works
                        logger.info(
                            f"Iteration {i}: Sending inference request after termination"
                        )
                        result = send_inference_request(
                            "The capital of France is", max_tokens=20
                        )
                        assert (
                            "paris" in result.lower()
                        ), f"Iteration {i}: Expected 'Paris' in response, got: '{result}'"
218

219
220
221
                        # Restart the terminated replica
                        logger.info(f"Iteration {i}: Restarting replica etcd-{i}")
                        etcd_cluster.restart_replica(i)
222
223
224
225
226
227


@pytest.mark.sglang
@pytest.mark.gpu_2
@pytest.mark.e2e
@pytest.mark.model(FAULT_TOLERANCE_MODEL_NAME)
228
@pytest.mark.timeout(600)
229
230
231
232
def test_etcd_ha_failover_sglang_disaggregated(
    request, predownload_models, set_ucx_tls_no_mm
):
    """
233
    Test ETCD High Availability with repeated node failures and recoveries in disaggregated mode using SGLang.
234
235
236
237

    This test:
    1. Starts a 3-node ETCD cluster
    2. Starts NATS, frontend, and both prefill and decode SGLang workers
238
239
240
241
242
243
244
245
    3. Cycles through each of the 3 replicas:
       - Terminate the replica by index
       - Send inference request to verify system still works
       - Restart the terminated node

    This ensures testing of:
    - ETCD leader termination
    - Frontend/worker disconnection from their connected ETCD replica
246
247
248
249
250
251
252
253

    Note: This test requires 2 GPUs to run decode and prefill workers on separate GPUs.
    """
    # Step 1: Start NATS server
    with NatsServer(request):
        logger.info("NATS server started successfully")

        # Step 2: Start 3-node ETCD cluster
254
255
        num_replicas = 3
        with EtcdCluster(request, num_replicas=num_replicas) as etcd_cluster:
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
            logger.info("3-node ETCD cluster started successfully")

            # Get the endpoints for all ETCD nodes
            etcd_endpoints = etcd_cluster.get_client_endpoints()
            logger.info(f"ETCD endpoints: {etcd_endpoints}")

            # Step 3: Start the frontend with ETCD endpoints
            with DynamoFrontendProcess(request, etcd_endpoints):
                logger.info("Frontend started successfully")

                # Step 4: Start the decode worker
                with DynamoWorkerProcess(request, etcd_endpoints, mode="decode"):
                    logger.info("Decode worker started successfully")

                    # Step 5: Start the prefill worker
                    with DynamoWorkerProcess(request, etcd_endpoints, mode="prefill"):
                        logger.info("Prefill worker started successfully")
                        # Small wait to ensure workers are fully ready
                        time.sleep(2)

276
277
278
                        # Step 6: Send initial inference request to verify system is working
                        logger.info("Sending initial inference request")
                        result = send_inference_request("What is 2+2? The answer is")
279
                        assert (
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
                            "4" in result.lower() or "four" in result.lower()
                        ), f"Expected '4' or 'four' in response, got: '{result}'"

                        # Step 7: Cycle through each replica to terminate/verify/restart
                        for i in range(num_replicas):
                            # Terminate a replica
                            logger.info(f"Iteration {i}: Terminating replica etcd-{i}")
                            etcd_cluster.terminate_replica(i)

                            # Send inference request to verify system still works
                            logger.info(
                                f"Iteration {i}: Sending inference request after termination"
                            )
                            result = send_inference_request(
                                "The capital of France is", max_tokens=20
                            )
                            assert (
                                "paris" in result.lower()
                            ), f"Iteration {i}: Expected 'Paris' in response, got: '{result}'"

                            # Restart the terminated replica
                            logger.info(f"Iteration {i}: Restarting replica etcd-{i}")
                            etcd_cluster.restart_replica(i)
303
304
305
306
307
308


@pytest.mark.sglang
@pytest.mark.gpu_1
@pytest.mark.e2e
@pytest.mark.model(FAULT_TOLERANCE_MODEL_NAME)
309
@pytest.mark.timeout(600)
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
def test_etcd_non_ha_shutdown_sglang_aggregated(request, predownload_models):
    """
    Test that frontend and worker shut down when single ETCD node is terminated using SGLang.

    This test:
    1. Starts a single ETCD node (no cluster)
    2. Starts NATS, frontend, and an SGLang worker
    3. Sends an inference request to verify the system works
    4. Terminates the single ETCD node
    5. Verifies that frontend and worker shut down gracefully
    """
    # Step 1: Start NATS server
    with NatsServer(request):
        logger.info("NATS server started successfully")

        # Step 2: Start single ETCD node using EtcdCluster with num_replicas=1
        with EtcdCluster(request, num_replicas=1) as etcd_cluster:
            logger.info("Single ETCD node started successfully")

            # Get the endpoint for the single ETCD node
            etcd_endpoints = etcd_cluster.get_client_endpoints()
            logger.info(f"ETCD endpoint: {etcd_endpoints}")

            # Step 3: Start the frontend with ETCD endpoint
            with DynamoFrontendProcess(request, etcd_endpoints) as frontend:
                logger.info("Frontend started successfully")

                # Step 4: Start an SGLang worker
                with DynamoWorkerProcess(request, etcd_endpoints, mode="agg") as worker:
                    logger.info("SGLang worker started successfully")
                    # Small wait to ensure worker is fully ready
                    time.sleep(2)

                    # Step 5: Send inference request to verify system is working
                    logger.info("Sending inference request")
                    result = send_inference_request("What is 2+2? The answer is")
                    assert (
                        "4" in result.lower() or "four" in result.lower()
                    ), f"Expected '4' or 'four' in response, got: '{result}'"

                    logger.info("System is working correctly with single ETCD node")

                    # Step 6: Terminate the ETCD node
                    logger.info("Terminating single ETCD node")
                    etcd_cluster.stop()

                    # Step 7: Wait and verify frontend and worker detect the loss
                    wait_for_processes_to_terminate(
                        {"Worker": worker, "Frontend": frontend}
                    )


@pytest.mark.sglang
@pytest.mark.gpu_2
@pytest.mark.e2e
@pytest.mark.model(FAULT_TOLERANCE_MODEL_NAME)
366
@pytest.mark.timeout(600)
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
def test_etcd_non_ha_shutdown_sglang_disaggregated(
    request, predownload_models, set_ucx_tls_no_mm
):
    """
    Test that frontend and workers shut down when single ETCD node is terminated in disaggregated mode using SGLang.

    This test:
    1. Starts a single ETCD node (no cluster)
    2. Starts NATS, frontend, and both prefill and decode SGLang workers
    3. Sends an inference request to verify the system works
    4. Terminates the single ETCD node
    5. Verifies that frontend and both workers shut down gracefully

    Note: This test requires 2 GPUs to run decode and prefill workers on separate GPUs.
    """
    # Step 1: Start NATS server
    with NatsServer(request):
        logger.info("NATS server started successfully")

        # Step 2: Start single ETCD node using EtcdCluster with num_replicas=1
        with EtcdCluster(request, num_replicas=1) as etcd_cluster:
            logger.info("Single ETCD node started successfully")

            # Get the endpoint for the single ETCD node
            etcd_endpoints = etcd_cluster.get_client_endpoints()
            logger.info(f"ETCD endpoint: {etcd_endpoints}")

            # Step 3: Start the frontend with ETCD endpoint
            with DynamoFrontendProcess(request, etcd_endpoints) as frontend:
                logger.info("Frontend started successfully")

                # Step 4: Start the decode worker
                with DynamoWorkerProcess(
                    request, etcd_endpoints, mode="decode"
                ) as decode_worker:
                    logger.info("Decode worker started successfully")

                    # Step 5: Start the prefill worker
                    with DynamoWorkerProcess(
                        request, etcd_endpoints, mode="prefill"
                    ) as prefill_worker:
                        logger.info("Prefill worker started successfully")
                        # Small wait to ensure workers are fully ready
                        time.sleep(2)

                        # Step 6: Send inference request to verify system is working
                        logger.info("Sending inference request")
                        result = send_inference_request("What is 2+2? The answer is")
                        assert (
                            "4" in result.lower() or "four" in result.lower()
                        ), f"Expected '4' or 'four' in response, got: '{result}'"

                        logger.info(
                            "System is working correctly with single ETCD node in disaggregated mode"
                        )

                        # Step 7: Terminate the ETCD node
                        logger.info("Terminating single ETCD node")
                        etcd_cluster.stop()

                        # Step 8: Wait and verify frontend and both workers detect the loss
                        wait_for_processes_to_terminate(
                            {
                                "Decode Worker": decode_worker,
                                "Prefill Worker": prefill_worker,
                                "Frontend": frontend,
                            }
                        )